TY - JOUR
T1 - Corneal epithelial Cl-dependent pump quantified
AU - Beekhuis, W H
AU - McCarey, B E
PY - 1986/11
Y1 - 1986/11
N2 - Pairs of rabbit corneas were perfused and corneal thickness monitored. The epithelial side of the preparation, and after stabilization also the endothelial side, was covered with silicone oil. A constant thinning of the cornea was observed at a rate of 11.1 microns hr-1 (= 1.0 micron L h-1 cm-2) S.D. 2.1, n = 9. This thinning was also present after endothelial removal: 12.3 microns hr-1, S.D. 1.6 (n = 5). Epithelial abrasion virtually abolished the thinning (2.5 microns hr-1, S.D. 1.89, n = 4), as did cooling from 34 to 0 degrees C. When the preparation was perfused with a Cl-free solution (SO4(2-) instead of Cl-, corrected for osmolarity with sucrose) no significant thinning of the preparation was observed (2.4 microns hr-1, S.D. 2.49, n = 4) after covering both surfaces with silicone oil. This simple set of experiments quantified the epithelial pump mechanism. The epithelial pump rate of about 1.2 microns L hr-1 cm-2 has to be taken into account when endothelial pump rates are measured in the in vitro preparation with intact epithelium.
AB - Pairs of rabbit corneas were perfused and corneal thickness monitored. The epithelial side of the preparation, and after stabilization also the endothelial side, was covered with silicone oil. A constant thinning of the cornea was observed at a rate of 11.1 microns hr-1 (= 1.0 micron L h-1 cm-2) S.D. 2.1, n = 9. This thinning was also present after endothelial removal: 12.3 microns hr-1, S.D. 1.6 (n = 5). Epithelial abrasion virtually abolished the thinning (2.5 microns hr-1, S.D. 1.89, n = 4), as did cooling from 34 to 0 degrees C. When the preparation was perfused with a Cl-free solution (SO4(2-) instead of Cl-, corrected for osmolarity with sucrose) no significant thinning of the preparation was observed (2.4 microns hr-1, S.D. 2.49, n = 4) after covering both surfaces with silicone oil. This simple set of experiments quantified the epithelial pump mechanism. The epithelial pump rate of about 1.2 microns L hr-1 cm-2 has to be taken into account when endothelial pump rates are measured in the in vitro preparation with intact epithelium.
KW - Animals
KW - Biological Transport, Active
KW - Chlorides/metabolism
KW - Cold Temperature
KW - Cornea/metabolism
KW - Epithelium/metabolism
KW - In Vitro Techniques
KW - Rabbits
KW - Silicone Oils
U2 - 10.1016/s0014-4835(86)80002-1
DO - 10.1016/s0014-4835(86)80002-1
M3 - Article
C2 - 3803457
SN - 0014-4835
VL - 43
SP - 707
EP - 711
JO - Experimental Eye Research
JF - Experimental Eye Research
IS - 5
ER -